We're Making Air Leak Tester Since 1962

 


    FL Series   Air Leak Tester

    Compact & Durable AIR LEAK TESTER
    STANDARDIZED SENSOR SAFETY BYPASS SYSTEM PROTECTSYOUR SENSOR AND PROMOTES A SECURE COST-EFFECTIVE LEAK TESTING SYSTEM

     

     

    More Detail  <PDF>

    Compact body,
    Collected Substantial Functions, High Durability and Easy Operation!

     

    INCREASED RELIABILITY

    COMPACT AND LIGHTWEIGHT

    EASY OPERATION

    FL-270 series:

     

    • For large leak measurement  Suited for large leak
      measurement (0.1 ~ 200 kPa)

    FL-280 series:

     

    • For medium leak measurement Suited for medium leak
      measurement (0.01 ~ 9.99 kPa)

    FL-293 & FL-294 series:

     

    • For minute leak measurement Suited for minute leak
      measurement (1~ 999 Pa)

    PRESSURE RANGE

    FL-293, 294 (Differential Preassure Leak Detecting Method)

    Model

    Test Pressure Range

    Pressure Range / Full Scale

    V

    ­5 ~ 90 kPa

    ­ 100 kPa

    UL

    1 ~ 9.99 kPa

    10.0 kPa

    L

    10~ 200 kPa

    0.2 Mpa

    M

    50~ 700 kPa

    1 Mpa

    H

    300 ~ 900 kPa

    1 MPa

    FL- 270, 273 (Gauge Pressure Leak Detecting Method)

    Model

    Test Pressure Range

    Pressure Range / Full Scale

    V

    ­5 ~ 90 kPa

    ­ 100 kPa

    L

    10 ~ 200 kPa

    0.2 Mpa

    M

    50 ~ 700 kPa

    1 Mpa

    H

    300~ 900 kPa

    1 MPa

    Corresponds to Work Volume AIR LEAK TESTER
    POWERFUL LINE OF LEAK TESTER DESIGNED TO THE PRODUCT VOLUME AND TO PERFORM HIGHLY ACCURATE LEAK TESTING

     

     

    More Detail  <PDF>

    Corresponds to Work Volume
    AIR LEAK TESTER

    Yearly Running Costs

    Dramatically Reduced !!

    FL-2600 & FL-3600 TURBO   For small Volumes

     

    • Recommended Volumes: 1 ml ~ 50 ml
      Reference Pressure Time : 1 ~ 15 sec
      Application Examples: Carburetors,Gas Valves,Injectors, Water Faucets, Magnet Valves, etc.

    FL-2700 & FL-3700 TURBO    For Medium Volumes

     

    • Recommended Volumes: 30 ml ~ 2 l
      Reference Pressure Time : 5 ~ 30 sec
      Application Examples: Canisters, Oil Filters, Oil Pumps, Engine Head Covers, Brake Parts, Die Cast Moldings, Petroleum Stoves, Water Heaters, Food Packages, Cans, etc.

    FL- 3800 TURBO  For Large Volumes

     

    • Recommended Volumes: 1 l ~ 50 l
      Reference Pressure Time : 10 ~ 200 sec
      Application Examples:
      Engine Assemblies, Mission Cases, Gas Meters, Hydraulic Pumps, Gas Tanks, Hydraulic Pumps, etc.
    Operation Pressure Range
    V
    -7~-90 kPa
    L
    10~99 kPa
    M
    50~700kPa
    H
    500~990kPa
    H1
    0.8~1.5MPa
    H2
    1.0~3.5MPa

    Model

    Volume Class

    FL - 2600
    1ml ~ 50ml
    FL - 2700
    30 ml ~ 2 l
    FL - 2710
    30 ml ~ 2 l
    FL - 2720
    30 ml ~ 2 l
    FL - 3600 TURBO
    1ml ~ 50ml
    FL - 3700 TURBO
    30 ml ~ 2 l
    FL - 3710 TURBO
    30 ml ~ 2 l
    FL - 2720 TURBO
    30 ml ~ 2 l
    FL - 3800 TURBO
    1 l ~ 50 l

     

    Multipurpose AIR LEAK TESTER
    MULTIPURPOSE LEAK TESTER WITH IMPROVED PERFORMANCE THROUGH FITTING MEASUREMENT METHOD

     

     

    More Detail  <PDF>

     

    Slim Design Accommodates
    Multiple Functions

    New Technology
    Leads to Time Reduction and High
    Accuracy Leak Testing !!

    FL- 601 Series
    Revolutionary differential pressure type master-less air leak tester takes our FL-600 series one step further into the future. This space-saving instrument will lead to gradual reduction in leading costs, and what's more, the detection time has become even shorter!

    • Conventional Leak Tester
    • Fitting Measurement Method
    • Self-Check Simplified Using the Maintenance Keys
    • Corresponds Quickly to Environmental
    • Change and Work Exchange (Fitting Function)
    • Large LCD Screen for Convenient Settings and Indications
    • Data Analysis, Estimate, and Maintenance
    • Shorter Testing Time and Higher Sensitivity When Used a Regulator and APU

    Operation Pressure Range

    Model

    Applied Pressure Range

     

    FL- 601 V

    -10~-80 kPa

     

    FL- 601 UL

    1~20 kPa

     

    FL- 601 L

    20~100kPa

    FL- 601 M

    100~700kPa

     

    FL- 601 H1

    0.5~2.0MPa

     

    FL- 601 H2

    1.0~5.0MPa

    Master-Less AIR LEAK TESTER
    SLEEK DESIGN MASTER-LESS SUPERIORITY

     

     

    More Detail  <PDF>

    Advanced Technology
    At A  Reasonable Coast.

    Sleek Design,
    Master-Less Superiority !!

     

    FL- 600 Series
    To see things that can't be seen, assign numerical Values to the unknown, and perform analysis. FL-600 Series - Leak Testers That Make A Science out of Differential Pressure

  • Shortened Testing Lime
    - Advanced data management allows reduction of testing time.
  • Detection Accuracy
    - Possible to conduct high S/N testing, eliminates temperature Influences and test various work parts.
  • Master-Less
    - Eliminates master management processes.
  • Improving outside factors
    - Problems involved with testing systems are assigned a numerical value consequently; problems are solved with effective countermeasures.
  • Corresponds to Multiple Work Parts
    - Flexibility allows multiple work parts adaptability.
  • Extensive Maintenance Functions
    - Automatic self-check functions for internal valves and various sensors. Flow Master and Calibrator allow volume testing and sensitivity verification.
  • Pressure Range

    Model
    Application Range (kPa)
    Setting Range
    (kPa)
    Indication Range (kPa)
    V
    -5~ -90
    0~90.0
    0~ -99.9
    L1
    10~ 99.9
    0~99.9
    0~99.9
    L2
    10~100
    0~100
    0~125
    M
    50~700
    0~700
    0~999

All items subject to prior Sale.